Re: Conditional Receiver Determination in ICO
HI,xpath is working based on our sender interface path, so here subString is wont work. Ask sender team to send the exact value. Regards,Mani
View ArticleRe: Solution Manager 7.1 installation failing
OK, I've tried a domain installation, by leaving the default "localdomain". But now I'm getting thefollowing (even more ridiculous) error: Component OraDbBuild: Context parameter dbSid must be a...
View ArticleRe: Solution Manager 7.1 installation failing
Hi everybody, thanks for your replies and suggestions, unfortunately none of this could solve the problem: @Sudheer G - I am installing the original oracle 10.2, which is coming with SAP. I have Oracle...
View ArticleRe: Problem at the step of Interscope Host Adaptor while configuring Managed...
Hi Nisha, We have installed SAP Management modules immediately after Wily installation.SAP Host agent is on the latest version 159. IntroscopeEnterpriseManager.log INFO: Application context...
View ArticleRe: Problem at the step of Interscope Host Adaptor while configuring Managed...
Hi Billy,There is only one entry WLY00001 in LMDB for standalone Wily.We have updated to WLY and restarted Wily introscope also.We are still getting the error. Regards,Sam
View ArticleRe: Problem at the step of Interscope Host Adaptor while configuring Managed...
Hi Karthikeyan, We have done the same.Uninstalled Wily and Diagnostic Agent.removed the entries.Installed them and configured.But still the error appears mentioning "Failed to establish connection to...
View ArticleRe: Problem at the step of Interscope Host Adaptor while configuring Managed...
Hi Divyanshu, We have checked 1.Note 1773617 - SAP Remote Support Component log files report exception "Failed to establish connection to Isengard Server As mentioned in the notes we are not able to...
View ArticleRe: EWA stops with a time out dump
Hi Jansi,the status is as follow:0SMD_PE2D /BI0/E0SMD_PE2D rows:244.120ratio: 100 %0SMD_PE2D /BI0/F0SMD_PE2D rows: 0ratio: 0 % 0SMD_PE2H /BI0/E0SMD_PE2H rows:...
View ArticleRe: CharM 7.1 - How to replace existing system from landscape incase its...
Hi, You can define a new logical component which includes the standby system in the landscape chain and replace the present logical component (with QA system) in the present project itself and...
View ArticleRe: Data receive failed error running merge partitions
Hi Patrick, It may be server stopped. Thanks & Regards,V Srinivasan
View ArticleRe: Adobe document Configuration for multiple ABAP system
Hi,As pert of the ADS functionality you can connect multiple abap system. If no ADS configuration steps have been performed yet after installation, perform the basic ADS configuration automaticallyCall...
View ArticleRe: Resist specified user to browse some fields in query
Hello, You mean to say that you want to hide selection screen field's based on user logged on?(Sorry if i'm wrong.) If so,please check this. at selection-screen output. if sy-uname = '...
View ArticleRe: Not able to expose OData Service
Hi Pradeep, As Jerry said try the link:"hostname:80<instance#>/workspace/session/a00/services/trendsData.xsodata" Please also check that your xsengine is up and...
View ArticleRe: If you know a standard transaction, how you can look for it on SAP Easy...
Hi Gilberto Parga, select sap menu label on the screen. and press CTRL+F. It will open you a pop-up screen having text 'Search in Menu Tree'. Enter t-code in the find field and select both the check...
View ArticleRe: For GR/IR account 211200. How to find Invoice amount and how to find GR...
Hi The cleared document can be identified by the table BSAS.. Line item existin in BSIS table is Still open Also, the field "Clearing doc" would be populated incase the doc is cleared Br, Ajay M
View ArticleRe: Quota generation through PT60
Hi Dinesh, I completely checked and we dont have quota type 01. We have 03/04/05 and attached screenshot of the same. Regards, S.Srikanth
View ArticleRe: Promotion Job Failed - Commit attempted and failed
Hi Are you using the user with admin privilege for logging into both servers and for doing promotion ? RegardsSandeep
View ArticleRe: Table to link Equipment/Serial No to Install Base No.
Hi,Have a look at the following links. http://scn.sap.com/thread/3262568 http://scn.sap.com/thread/1108681 Hope this helps. Regards,Naresh
View ArticleRe: Web Intelligence Document Error Occurs with Date Prompt Only
Hi I had similar problem.Is your date object a time stamp type?Please change to date type. RegardsSandeep
View Article