Re: Single cycle count scheduling

$
0
0

As I mentioned already, during Maintenance, because of some test run, some counter might have been consumed.

 

Even there is no change in counter value, measurement document during TECO only will update the Completion Reading in IP10. Creating Manual Measurement documents or through Integration with Production will not be considered to postpone the next Planned counter based on shift factor.

 

As there is no link between Manual Measurement document & PM Order completion, system can't recognize that latest reading as Completion reading & it can't plan from there.

 

Also, insisted you to go with new Maintenance plan with same set of data. Else, click on that marked row & click the calculator. See what is the calculation happened.

 

Just by seeing IP10 screen shot (without understanding about the other details changes), its not possible to give any kind of solution.